Industry Projects
Construction Projects
Timber Structure Wooden House
Internship Program-Project Program-Product Dev, Program
UNIT I
Four Exmples from Text Book will be given trainingOn software listed For the program Four problem will be given for self training with software to Trainee
The company STC "APM" carried out a strength calculation of a wooden house made of glued laminated timber.
Place of construction of a residential building: Moscow region.
The calculation was carried out in the APM CivilEngineering software product taking into account the requirements ofSP 20.13330.2011 "Loads and Impacts".
UNIT IV
Four Exmples from Text Book will be given trainingOn software listed For the program Four problem will be given for self training with software to Trainee
A static calculation of the structure for the main combination of loads is carried out. Analysis of the results of the static calculation shows that at the specified design loads, the equivalent stresses arising in the frame structural elements when using the specified sections do not exceed the tensile strength of the materials used (design resistance), i.e. the required strength is provided. In the most unfavorable case of loading, the safety factor for the design resistance is greater than one and is equal to 2.5.
The maximum deflections of the building structure, resulting from the combination of its own weight and external loads, do not exceed the permissible limit. That is, the necessary rigidity of the load-bearing frame is ensured.
Summarizing the results obtained, it can be concluded that the structure of the building is able to bear the loads applied to it, corresponding to the construction area, and does not require additional measures to increase the strength characteristics.
The work carried out showed the applicability of the APM Civil Engineering software package for solving complex problems of strength analysis of wooden structures.

UNIT II
Four Exmples from Text Book will be given trainingOn software listed For the program Four problem will be given for self training with software to Trainee
The design model of a residential building is built on the basis of the architectural model provided by the customer. A general analysis model made in the APM Structure3D module.
The model of a residential building is based on a previously built foundation that is not involved in the calculation. For the support points of the columns, a rigid fastening scheme is adopted with a ban on all movements and rotation angles.
Effective loads:
Constant loads. Permanent loads primarily include the dead weight of the structure and the weight of the roof covering.Temporary loads. Weight of equipment, people, animals, stored materials and products.Snow loads according to SNiP 2.01.07-85*.Wind loads according to SNiP 2.01.07-85*.


UNIT III
Four Exmples from Text Book will be given trainingOn software listed For the program Four problem will be given for self training with software to Trainee
A static calculation of the structure of a residential building was carried out for the main load combinations, for three design cases (combinations of load cases). Maps of the stressed and deformed state of the structure under the corresponding loading options are obtained.